This content is provided for educational purposes only. AWC® specializes in advanced membrane chemicals and technical solutions - we do not sell water treatment equipment. If you’re looking for support with maximizing recovery, extending membrane life, or reducing operating costs, our team is here to help.

Contact us

The buildup of rejected solutes in a thin boundary layer at the membrane surface, which raises the salt concentration there above that of the bulk feed-concentrate stream.

Concentration polarization, or CP, occurs in every reverse osmosis and nanofiltration element. Water passes through the membrane while dissolved ions are rejected, and those ions collect in a laminar boundary layer faster than crossflow and back-diffusion can carry them away. P. L. T. Brian of the Massachusetts Institute of Technology analyzed the effect for reverse osmosis desalination in 1965, in research for the US Office of Saline Water. It is expressed as the concentration polarization factor, β = Cm / Cb, where Cm is the solute concentration at the membrane wall and Cb is the concentration in the bulk stream. For a high-rejection membrane, film theory gives β ≈ exp(Jw / k), where Jw is the permeate flux and k is the mass transfer coefficient set by crossflow velocity and feed spacer geometry.

The higher solute concentration at the wall raises osmotic pressure at the membrane surface, which lowers net driving pressure and reduces flux. It also increases salt passage, because salt diffuses through the membrane in proportion to the wall concentration. For scale control, the effect on saturation is larger still. Scale forms at the membrane surface, so the saturation level that governs precipitation is the bulk concentrate value multiplied by β. Design guidelines commonly limit the factor to about 1.2, which in turn caps permeate recovery from a single 40-inch element at roughly 18 percent.

CP is highest where flux is high and crossflow is low. Lead elements operate at the highest flux, while tail elements receive the most concentrated water at the lowest crossflow velocity, and both positions can exceed the saturation limits predicted from bulk chemistry. An antiscalant dose calculated from bulk concentrate chemistry alone will therefore understate the scaling potential at the membrane wall. PROTON® calculates the concentration polarization factor alongside its scaling and dosing projections for each system design.